“Alertmanager”的版本间的差异
跳到导航
跳到搜索
第102行: | 第102行: | ||
=see also= | =see also= | ||
https://prometheus.io/docs/alerting/alertmanager/ | https://prometheus.io/docs/alerting/alertmanager/ | ||
+ | |||
+ | [https://www.jianshu.com/p/239b145e2acc Prometheus Alertmanager报警组件] | ||
[https://blog.csdn.net/qq_25178661/article/details/86690729 good-prometheus + AlertManager 实现对多node节点CPU和内存信息的监控] | [https://blog.csdn.net/qq_25178661/article/details/86690729 good-prometheus + AlertManager 实现对多node节点CPU和内存信息的监控] |
2020年6月24日 (三) 10:31的版本
目录
* my email
@126.com
授权密码
* intro
告警能力在Prometheus的架构中被划分为两个部分,在Prometheus Server中定义告警规则以及产生告警,Alertmanager组件则用于处理这些由Prometheus产生的告警。Alertmanager即Prometheus体系中告警的统一处理中心。 Alertmanager提供了多种内置第三方告警通知方式,同时还提供了对Webhook通知的支持,通过Webhook用户可以完成对告警更多个性化的扩展。
* ins
** using docker or docker-composer
用自带的 compose
https://hub.docker.com/r/prom/alertmanager/dockerfile
- docker only
docker pull prom/alertmanager docker run --name alertmanager -d -p 9093:9093 -v /path/to/config.yml:/etc/alertmanager/conf/config.yml prom/alertmanager
* conf
rules vim node-up.rules groups: - name: node-up rules: - alert: node-up expr: up{job="node-exporter"} == 0 for: 15s labels: severity: 1 team: node annotations: summary: "{{ $labels.instance }} 已停止运行超过 15s!" 说明一下:该 rules 目的是监测 node 是否存活,expr 为 PromQL 表达式验证特定节点 job="node-exporter" 是否活着,for 表示报警状态为 Pending 后等待 15s 变成 Firing 状态,一旦变成 Firing 状态则将报警发送到 AlertManager,labels 和 annotations 对该 alert 添加更多的标识说明信息,所有添加的标签注解信息,以及 prometheus.yml 中该 job 已添加 label 都会自动添加到邮件内容中,更多关于 rule 详细配置可以参考 #告警解除
* 自定义告警规则
** CPU load 自定义告警规则
- alert: high_load-85per expr: (100-(avg(irate(node_cpu_seconds_total{mode="idle"}[5m]))by (job)) * 100) > 80 #expr: sum(avg without (cpu)(irate(node_cpu{mode!='idle'}[5m]))) by (instance) > 0.81 #expr: node_load1 > 0.2 for: 10m labels: severity: page annotations: summary: "Instance {{ $labels.instance }} under high load" description: "{{ $labels.instance }} of job {{ $labels.job }} is under high load more than 12 minutes." FIRING 才会 send email
** 内存自定义告警规则
#rules file 注意空格在前面哦 - alert: hostMemUsageAlert expr: ((node_memory_MemTotal_bytes -(node_memory_MemFree_bytes+node_memory_Buffers_bytes+node_memory_Cached_bytes) )/node_memory_MemTotal_bytes ) * 100 > 90 #expr: (node_memory_MemTotal - node_memory_MemAvailable)/node_memory_MemTotal > 0.85 for: 1m labels: severity: page annotations: summary: "Instance {{ $labels.instance }} MEM usgae high" description: "{{ $labels.instance }} MEM usage above 85% (current value: {{ $value }})"
成功的自定义报警规则 2020 https://www.shared-code.com/article/84
这个成功的 上面的不成功
((node_memory_MemTotal_bytes -(node_memory_MemFree_bytes+node_memory_Buffers_bytes+node_memory_Cached_bytes) )/node_memory_MemTotal_bytes ) * 100 > 90
** 磁盘自定义告警
- alert: LowDiskSpaceNodeFilesystemUsage expr: 100 - (node_filesystem_free_bytes{mountpoint="/",fstype=~"ext4|xfs"} / node_filesystem_size_bytes{fstype=~"ext4|xfs"} * 100) > 80 for: 1m labels: severity: warning annotations: summary: "Instance {{ $labels.instance }} :{{ $labels.mountpoint }} 分区使用率过高" description: "{{ $labels.instance }} : {{ $labels.job }} :{{ $labels.mountpoint }} 这个分区使用大于百分之80% (当前值:{{ $value }})"
see also
https://prometheus.io/docs/alerting/alertmanager/